ET 600 Conditioning of Room Air
Education / GUNT Hamburg / Thermal Engineering and HVAC / Refrigeration and Air Conditioning Technology /
description

In many daily situations the condition of the ambient air does not meet requirements for e.g. a tropical greenhouse, the manufacture of sensitive components or even comfortable offices. The flow velocity, temperature and humidity of the air can be modified by air conditioning systems in accordance with the requirements for the desired room climate.
  The trainer ET 600 examines the operation and effect of the individual components of an air conditioning system. ET 600 includes all the components also used in building services engineering. Particular importance was placed on the use of original components.  
  For air conditioning, air cooler (direct evaporator with condensing unit), steam humidifier, fan, air preheaters and reheaters are arranged in an open air duct. Each of these components can be switched on or off individually. The effect of each individual component on the conditioning of the air is as interesting as the effect of any combination of components.
  Sensors record the air temperature and air humidity before and after each stage as well as the pressures and temperatures of the refrigerant. The measured values can be read on digital displays. At the same time, the measured values can also be transmitted directly to a PC via USB. The data acquisition software is included.
  The well-structured instructional material sets out the fundamentals and provides a step-by-step guide through the experiments.

 
Learning Objectives / Experiments

- Air conditioning of room air
  * set-up of an air conditioning system: main

    components and their function
  * variables in air conditioning
  * measure temperature and air humidity
  * effect of the air flow
  * changes of state in the h-x diagram
- Set-up of a refrigeration system: main

  components and their function
- Measurements in the refrigeration circuit
  * cyclic process in the log p-h diagram
  * determine heating and cooling capacities

Specification
[1] Effect of typical air conditioning system components on the conditioning of room air
[2] Air conditioning system with open air duct
[3] Air conditioning system with air cooler, steam humidifier, fan, air preheaters and reheaters
[4] All components can be switched on and off individually
[5] Determination of the air flow by differential pressure measurement using an inclined tube manometer
[6] Combined sensors for the air humidity and temperature before and after each stage 
[7] Sensor for the pressure and temperature of the refrigerant 
[8] Data acquisition with LabVIEW software under Windows XP or Windows Vista via USB
[9] Software with representation in the log p-h and h-x diagram
[10] Refrigerant R134a, CFC-free 
 
Technical Data
Steam humidifier 
- power consumption: 4kW
- steam capacity: 5,5kg/h, switchable in three stages
Fan
- power consumption: 190W
- max. volume flow: 810m³/h
- speed: 500...1150min-1
- dpmax: 420Pa
Air preheater: 2kW, switchable in two stages
Air reheater: 1kW, switchable in two stages
Air duct, WxH: 300x350mm
Direct evaporator as air cooler: 6kW
Condensing unit
- power consumption: 968W at 5/25°C
- refrigeration capacity: 2,3kW at 5/25°C
Measuring ranges 
- differential pressure (air flow): 0...100Pa
- temperature: 5x 0...50°C, 4x -100...200°C
- humidity: 5x 0...100%
- pressure (refrigerant): 2x 0...16bar
- flow rate (refrigerant): 8...102L/h
 
Dimensions and Weight
LxWxH: 2565x790x1750mm
Weight: approx. 180kg
Required for Operation

400V, 50Hz, 3 phases or 230V, 60Hz, 3 phases

Water connection and drainage

Scope of Delivery

1 trainer, filled with refrigerant

1 LabVIEW software CD + USB cable

1 set of instructional material